• Открыт набор модераторов на нашем форуме. Заявку можно подать в разделе "Вопросы и предложения" > "Набор модераторов".

M914: TMC Bump Sensitivity

  • Просмотры Просмотры: 25
  • Последнее обновление Последнее обновление:
  • Описание
    Some TMC stepper drivers can detect when they bump into something that causes them to stop moving. This feature is so sensitive that it can actually take the place of traditional endstops. Use this command to set the bump sensitivity for the X, Y, and Z stepper drivers.
    Примечание
    Set all *_HOME_BUMP_MM values to 0 for best results.
    Set the default stall thresholds with *_STALL_SENSITIVITY.
    Compatible with TMC2130 and TMC2209.
    Sensitivity TMC2209 Others LOWEST0+63HIGHEST255-64
    High sensitivity may produce false positives.
    Low sensitivity may fail to trigger.
    Использование
    M914 [I<index>] [X<int>] [Y<int>] [Z<int>]
    Параметры
    [I<index>]
    (>=1.1.9) Index for dual steppers. Use I1 for X2, Y2, and/or Z2.
    [X<int>]
    Sensitivity of the X stepper driver.
    [Y<int>]
    Sensitivity of the Y stepper driver.
    [Z<int>]
    Sensitivity of the Z stepper driver.